power meter PCE-PA 8000
$2,409.00
The PCE-PA 8000 is a state of the art portable handheld Power Meter used for consistently accurate and reliable testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This versatile and highly effective power quality analyzer not only measures multiple electrical properties in real time, but also saves the measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using Microsoft Excel.
– True RMS measurement for ACA, ACV
– True power: W, KW, MW
– VA, KVA, MVA, VAR, KVAR, MVAR
– PF (power factor), phase angle (Φ)
– KWH, KVAH, KVARH, PFH
– Voltage measurement range: 10 … 600 ACV
– Current measurement range: 0.2 … 1200 ACA
– Real-time current, voltage and power consumption measurement
– Built-in data recorder with adjustable sample rate: 2 … 7,200 sec.
PCE-PA 8000 Power Meter
Current monitored in Real-time, consumption of voltage and power measurement provided / integrated data recorder with adjustable rate meter / this unit Includes clamps for current rate, as well as alligator clips, test leads, SD card memory capability, and a 2-year warranty covering instances of manufacturer defects
The PCE-PA 8000 is a versatile portable / handheld Power Meter primarily deployed for such specific uses as the testing and inspection of 3-phase / 4-wire, 3-phase / 3-wire, 1-phase / 2-wire and 1-phase / 3-wire electrical circuits. This professional grade power quality analyzer efficiently measures multiple electrical properties in real time, the unit also has the abilty to save critical measurement data in .xls format to the included SD card memory for quick and easy data transfer and analysis using the Microsoft Excel platform.
The PCE-PA 8000 Power Meter consistently provides reliably true RMS measurements of current and voltage. The Power Meter also features the multi-function command capability to accurately determine power factor (PF), phase angle (Φ), active power, apparent power and reactive power. The three (3) current clamps included with the Power Meter can be used on a variety of wires and cables with a diameter of 2.0" / 50 mm, allowing for use with the power grid. Delivery contents also include four (4) alligator clips, four (4) test leads, and an SD card. For real-time current, voltage and power consumption measurements at a glance, the PCE-PA 8000 also features an easy-to-read 3.7" / 94 mm (320 x 240 pixel) LCD screen with backlight.
HIGHLIGHTS
- True power: W, KW, MW
- VA, KVA, MVA, VAR, KVAR, MVAR
- PF (power factor), phase angle (Φ)
- KWH, KVAH, KVARH, PFH
- Voltage measurement range: 10 ... 600 ACV
- Current measurement range: 0.2 ... 1200 ACA
- Real-time current, voltage and power consumption measurement
- Built-in data recorder with adjustable rate: 2 ... 7,200 sec.
- Saves date- and time-stamped measurement data sets
- Complies with IEC 1010 and CAT III 600 V safety standards
- Includes current clamps, alligator clips, test leads, SD card memory and 2-year warranty against manufacturer defects
- Optional ISO calibration certificate, USB data cable with software and spare AC power adapter sold separately - see accessories for details
SPECIFICATION
Voltage (ACV) | ||
Measurement range | Resolution | Accuracy |
10 V ... 600 V (phase to neutral) | 0.1 V | ±(0.5 % + 0.5 V) |
10 V ... 600 V (phase to neutral) | ||
Current (ACA) | ||
Measurement range | Resolution | Accuracy |
20 A | 0.001 A (< 10 A) 0.01 A (≥ 10 A) |
±(0.5 % + 0.1 V) |
200 A | 0.01 A (< 100 A) 0.1 A (≥ 100 A) |
±(0.5 % + 0.5 A) |
1200 A | 0.1 A (< 1000 A) 1 A (≥ 1000 A) |
±(0.5 A + 5 A) |
Active power | ||
Measurement range | Resolution | Accuracy |
0 KW ... 9.999 KW | 0.001 KW | ±(1 % + 0.008 KW) |
10 KW ... 99.99 KW | 0.01 KW | ±(1 % + 0.008 KW) |
100 KW ... 999.9 KW | 0.1 KW | ±(1 % + 0.8 KW) |
1 MW ... 9.999 MW | 0.001 MW | ±(1 % + 0.008 MW) |
Apparent power | ||
Measurement range | Resolution | Accuracy |
0 KVA ... 9.999 KVA | 0.001 KVA | ±(1 % + 0.008 KVA) |
10 KVA ... 99.99 KVA | 0.01 KVA | ±(1 % + 0.08 KVA) |
100 KVA ... 999.9 KVA | 0.1 KVA | ±(1 % + 0.8 KVA) |
1 MVA ... 9.999 MVA | 0.001 MVA | ±(1 % + 0.008 MVA) |
Reactive power | ||
Measurement range | Resolution | Accuracy |
0 KVAR ... 9.999 KVAR | 0.001 KVAR | ±(1 % + 0.008 KVAR) |
10 KVAR ... 99.99 KVAR | 0.01 KVAR | ±(1 % + 0.08 KVAR) |
100 KVAR ... 999.9 KVAR | 0.1 KVAR | ±(1 % + 0.8 KVAR) |
1 MVAR ... 9.999 MVAR | 0.001 MVAR | ±(1 % + 0.008 MVAR) |
Active energy | ||
Measurement range | Resolution | Accuracy |
0 KWh ... 9.999 KWh | 0.001 KWh | ±(1 % + 0.008 KWh) |
10 KWh ... 99.99 KWh | 0.01 KWh | ±(1 % + 0.08 KWh) |
100 KWh ... 999.9 KWh | 0.1 KWh | ±(1 % + 0.8 KWh) |
1 MWh... 9.999 MWh | 0.001 MWh | ±(1 % + 0.008 MWh) |
Apparent energy | ||
Measurement range | Resolution | Accuracy |
0 KVAh ... 9.999 KVAh | 0.001 KVAh | ±(2 % + 0.008 KVAh) |
10 KVAh ... 99.99 KVAh | 0.01 KVAh | ±(2 % + 0.08 KVAh) |
100 KVAh ... 999.9 KVAh | 0.1 KVAh | ±(2 % + 0.8 KVAh) |
1 MVAh... 9.999 MVAh | 0.001 MVAh | ±(2 % + 0.008 MVAh) |
Reactive energy | ||
Measurement range | Resolution | Accuracy |
0 KVARh ... 9.999 KVARh | 0.001 KVARh | ±(2 % + 0.008 KVARh) |
10 KVARh ... 99.99 KVARh | 0.01 KVARh | ±(2 % + 0.08 KVARh) |
100 KVARh ... 999.9 KVARh | 0.1 KVARh | ±(2 % + 0.8 KVARh) |
1 MVARh... 9.999 MVARh | 0.001 MVARh | ±(2 % + 0.008 MVARh) |
Power factor | ||
Measurement range | Resolution | Accuracy |
0 ... 1 | 0.01 | ±0.04 |
Phase angle | ||
Measurement range | Resolution | Accuracy |
-180º ... 180º | 0.1º | ±1º |
Frequency | ||
Measurement range | Resolution | Accuracy |
45 Hz ... 65 Hz | 0.1 Hz | 0.1 Hz |
General specifications | ||
Display | 3.7" / 94.0 mm LCD (320 x 240 pixel) with backlight | |
Electrical properties | ACV, ACA, active power, apparent power, power factor, phase angle, mains frequency | |
Voltage range | 10 ... 600 ACV, automatic range selection | |
Safety standards | Complies with IEC 1010, CAT III 600 V | |
ACV input resistance | 10 MΩ | |
Operation frequency of current clamps | 40 Hz ... 1 kHz | |
Tested operation frequency of current clamps | 45 Hz ... 65 Hz | |
Overload protection | ACV / 720 V RMS | |
ACA | 1300 A with current clamps | |
Memory | SD card, up to 16 GB | |
Real-time display refresh rate | 1 second | |
Data logger | Yes, fully integrated | |
Data logger sample rate | Adjustable, 2 ... 7,200 seconds | |
Data output | USB or RS-232, depending on the connection cable | |
Operating temperature | 0º C ... 50º C / 32° F ... 122° F | |
Operating humidity | < 80 % RH | |
Power supply | 8 x 1.5 V AA batteries / AC power adapter | |
Input current | Meter: 300 mA DC Clamp: 34 mA DC |
|
Max. diameter | 2" / 50 mm | |
Weight | Meter: 948 g / 2.09 lbs (with batteries) Clamp: 467 g / 1.03 lbs (with cable) |
|
Dimensions | Meter: 225 x 125 x 64 mm / 8.8 x 4.9 x 2.5" | |
Clamp: 210 x 64 x 33 mm / 8.2 x 2.5 x 1.2" | ||
Jaw: 86 mm / 3.3" (exterior) |
DELIVERY SCOPE
3 x Current clamps
4 x Alligator clips
4 x Test leads
1 x SD card
8 x 1.5 V AA batteries
1 x AC power adapter
1 x User manual